The renovation is built around two main strategies. The first aims to create more space open to the climate and to natural light: the area that was originally a patio, then later enclosed, is now transformed into a greenhouse and expanded to two floors, creating several benefits. First, it provides a sheltered space usable in mid-season and winter, protected from rain and wind, yet still connected to the outdoors, with temperatures averaging 5-10°C higher than outside. Second, it brings far more daylight into the neighbouring classrooms than before. Finally, it acts as a thermal buffer between the harsh exterior and the tempered interior, helping cut overall heating demand by more than half. The second strategy targets the building envelope, with reinforced insulation on opaque walls and new, more easily operable window frames.
The project began with a thorough diagnosis of the existing building, combining in-situ monitoring, an analysis of energy consumption, and a study of the thermal envelope, resulting in an accurately calibrated thermal model. This fieldwork made it possible to accurately assess the impact of each proposed intervention.
Daylight Autonomy DA [300]
-
0
-
10
-
20
-
30
-
50
-
60
-
70
-
80
-
90
-
100
Daylight Autonomy calculates the percentage of time each point in space receives 300 lux or more naturally.
300 lux gives the impression of a daylit space
Greenhouse temperatures
Thermodynamic balance
Reduction in annual heating demand
-
0
-
5
-
10