MainSilhouetteArtboard 1
Artboard 1
Chateau Lafite_Axo_silhouette
Artboard 3
Artboard 1
Artboard 3
Ghent_Axo_silhouette
GL Pau_Axo_silhouette-01
EMVS_Axo_silhouette
Ministerio_Axo_silhouette
Hamburg_Axo_silhouette
Cafferata_Axo_silhouette
Halle bioclimatique_Axo_silouhette-small
Palenque_Axo_silhouette
Crystal Palace_Axo_silhouette
Carriego_Axo_silhouette
School of Architecture ENSAP - Lille
Lille, France
ENSAP
Dadour de Pous Architecture
2022
9800 m²
Renovation + extension
Activities
Built

The renovation is built around two main strategies. The first aims to create more space open to the climate and to natural light: the area that was originally a patio, then later enclosed, is now transformed into a greenhouse and expanded to two floors, creating several benefits. First, it provides a sheltered space usable in mid-season and winter, protected from rain and wind, yet still connected to the outdoors, with temperatures averaging 5-10°C higher than outside. Second, it brings far more daylight into the neighbouring classrooms than before. Finally, it acts as a thermal buffer between the harsh exterior and the tempered interior, helping cut overall heating demand by more than half. The second strategy targets the building envelope, with reinforced insulation on opaque walls and new, more easily operable window frames.

The project began with a thorough diagnosis of the existing building, combining in-situ monitoring, an analysis of energy consumption, and a study of the thermal envelope, resulting in an accurately calibrated thermal model. This fieldwork made it possible to accurately assess the impact of each proposed intervention.

Daylight Autonomy DA [300]

Daylight legend

Greenhouse temperatures

Daily range of exterior temperature
Monthly exterior average
Daily range of greenhouse air temperature
Monthly average of greenhouse air temperature
Alternative with single glazing

Thermodynamic balance

Heating demand
Solar heat gains
Heat gains by electric equipment
Heat gains by electric lighting
Heat gains by people
Heat loss by infiltration
Heat loss by ventilation
Heat loss by window conduction
Heat loss by opaque conduction
Storage

Reduction in annual heating demand

  • 0
  • 5
  • 10
kWh

"The École d'architecture et de paysage de Lille (Lille School of Architecture and Landscape) was built in 1977. It went through a series of renovations and extensions up to 2005, including a major rehabilitation of the main building in 1993." "The project is committed to respecting the 20th-century built heritage represented by Pierre Edlin's building. It aims to show that the building can truly adapt to today's challenges and can create comfortable, sustainable spaces of 'high quality of use.' To achieve this, the project intends to make the most of the resources the site offers by pursuing the following intentions:
-Implement a bioclimatic strategy at the scale of the site
-Restore a clear reading of the architecture on the façades
-Enhance, beautify and make use of the flat roof terraces
-Highlight the existing geometries and the relationships between inside and outside
-Restore sustainable comfort
-Make room for nature"

"The approach cannot be reduced to a single question of energy savings. The brief explicitly calls for removing the external insulation added in 1993. This shows that solutions only last if they respect the existing sites and remain architecturally coherent.
We therefore believe that no effort to improve energy performance can sidestep the notion of sustainable comfort, which links energy performance to how well a place works for the people who use it. Every proposed system, whether passive or active, must also be judged on its ability to create spaces that are pleasant to live in and a source of well-being. The planned intervention aims to recover the building's original spirit, which was freer and more fluid. That spirit was gradually lost over time as successive partitions were added to adapt the building to changing needs and teaching approaches."

Agence Dadour de Pous

The project won the Grand Prix d'a 2024.

images by Philippe Ruault

Project
existing

Lille has an oceanic climate (Cfb), generally cool and humid, with rainfall and wind throughout the year, particularly in autumn and winter. In winter, the average high temperature is around 7°C, with occasional lows down to -3°C. The potential for passive solar heat gain is moderate but useful and is concentrated on the south-east and south-west orientations: vertical glazed surfaces facing these directions help raise indoor temperatures naturally. In summer, the average high temperature is 23°C, with occasional peaks up above 27ºC. Sunshine levels are moderate, with radiation that is mostly diffuse. On the hottest days, the gap between day and night temperatures makes it possible to use night cooling and the building's thermal mass to bring indoor temperatures back within the comfort range. The prevailing winds come from the west-south-west and east-north-east, with a high average speed of 4.2 m/s.

Climate summary

Average temperature
t
(°C)
Avg. min. and avg. max. temperature
t
(°C)
Relative humidity
w
(%)
Daily diffuse solar radiation
r
(100xW/m²)
Daily total solar radiation
r
(100xW/m²)
Wind speed
a
(m/s)
Monthly precipitations
w
cm
Daily range
t
(°C)
Temperature predictions for 2050
t
(°C)

Sun path

Solar altitude
s
  • 0
  • 240
  • 480
  • 720
  • 960
  • 1200
kWh/m2

Wind rose

Wind frequency
a
  • 0
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
m/s
Close